Aluminium shopfronts combine a metal framing system with display glazing and entrance doors. The frame defines the frontage, supports the agreed glazing arrangement and provides an interface for door hardware. British Shopfronts handles new and replacement aluminium shopfront enquiries across London and the UK, from individual retail units to commercial entrance projects.

The most useful starting point is a layout that works for your premises: where the entrance sits, which areas need uninterrupted display glass and how people, deliveries and after-hours closure will be managed.

Coordinate the frontage with aluminium doors and aluminium windows where those systems form part of the brief. For a wider glazed facade project, see curtain walling.

Framed glazed retail frontage with a central entrance
Framed glazed frontage — a visual example of the layout.

Frame layout, glazing and finish

Vertical and horizontal frame divisions affect both the appearance and the usable pane sizes. A wide glass display, a central double entrance and an offset single door each create different frame and hardware requirements. Include the fascia/signage zone, floor level and any existing shutter in the design discussion.

Powder-coated finishes can be considered around your branding. Agree the actual colour reference and finish rather than relying on a phone-screen image. If you are retaining part of an existing frontage, discuss whether the new and old sections can achieve a satisfactory visual match.

Glazing should be selected for its position and purpose. Toughened and laminated options have different characteristics; neither a frame colour nor the word “commercial” establishes the appropriate glass specification. The survey and quotation should identify the proposed glazing rather than leaving it as unspecified glass.

Thermal performance and the frame system

If heat retention or comfort near the frontage is important, ask how the proposed frame and glazing work together. A thermally broken aluminium profile interrupts part of the conductive path through the metal; it is a feature of the actual frame system, not of a powder-coated colour. A glass-only U-value does not describe the thermal performance of the complete framed frontage.

The specification should also distinguish solar control from insulation. Reducing heat flow through the assembly and limiting solar heat entering through glass are different objectives. Describe the frontage orientation, daylight needs and any comfort problem so the appropriate performance brief can be considered. No energy-saving percentage or thermal rating is promised without the offered system’s data.

Design choice Useful question before approval
Frame divisions Will the proposed mullions and transoms leave the display view and door clearances you need?
Door hardware Are locks, closers and pivots identified rather than described only as standard ironmongery?
Frame finish Is the colour/finish reference agreed, including any retained neighbouring sections?
Building junctions Who deals with the head, side and floor interfaces and surrounding making good?

Entrance doors and daily use

Single or double doors, manual operation or automation, handles, closers and locks all affect the finished entrance. Think about delivery access as well as customer entry. Threshold levels, door swing and nearby obstructions should be reviewed together, especially where the entrance opens onto a busy pavement or constrained internal space.

If the proposed doorway needs automation, use our automatic door comparison before finalising frame divisions. For an existing door fault, our shopfront repair service may be the more appropriate starting point.

Replacement without overlooking the surrounding opening

Replacing an aluminium shopfront involves more than matching its visible width and height. Removal can reveal uneven surfaces or deteriorated fixing areas. Existing signage, security shutters, internal finishes and floor levels may constrain the installation sequence. Identify these interfaces early so removal, fitting and making good are assigned clearly.

What affects the quotation?

Opening size, frame divisions, glazing, entrance arrangement, hardware and finish all influence the supply specification. Removal, disposal, working access, lifting requirements and the site programme affect installation. Send photographs of the full frontage, both sides of the doorway and the head above the opening, together with approximate sizes and your postcode.

Aluminium shopfront FAQs

Can I replace the doors without replacing the entire frame?

Possibly. The existing frame, door dimensions, hinges, closer and locking arrangement need checking. A compatible replacement or repair may be practical where the surrounding frame is sound.

Are aluminium and glass shopfronts alternatives?

Not always. Aluminium shopfronts usually include glass. The meaningful comparison is often an aluminium framed system versus a glass-led or frameless arrangement.

Can I match an existing brand colour?

Provide the required colour reference or a physical sample. Availability and the achievable match should be agreed before ordering, particularly beside an older finish.

Can shutters sit behind or in front of the frontage?

Different arrangements may be possible. The available headroom, guides, fixing surfaces, signage and doorway must be assessed together.

Does the quote include removal and making good?

Only where stated. Ask the quotation to identify removal, disposal, sealant/junction work and surrounding finishes so responsibilities are clear.

Can you quote a project outside London?

Yes. Include the postcode, site access and whether you require supply only or installation so the location can be planned into the quotation.

View frontage examples, read installation guidance or request an aluminium shopfront quote.